El Niño 2026 raises the risk of extreme heat in Peru. Learn how EDGE and LEED certifications help buildings stay cool, efficient and operational.

Peru's Multisectoral Committee ENFEN has kept its Coastal El Niño alert in place and does not rule out the event reaching a significant magnitude, with impacts lasting into 2027. For Peru's coast, this means more days of intense heat, higher humidity and heavy rainfall in some areas. For the real estate sector, the underlying question is different: how prepared are our buildings to operate under these conditions?

The answer doesn't depend on the weather alone, but on how each property was designed, built and operated. Two offices in the same district can experience the same heat wave in completely different ways. One, with an unshaded glass façade and air conditioning units running at full capacity, overheats and sends its electricity bill soaring. The other, designed with efficiency and comfort in mind, maintains stable conditions without overloading its systems.

That difference is exactly what sustainability certifications such as EDGE and LEED aim to secure.

El Niño raises the risk; the building determines what happens inside

El Niño is the abnormal warming of the equatorial Pacific Ocean. In Peru, it can bring higher temperatures along the coast, increased humidity, heavy rainfall in the north and pressure on urban infrastructure.

Not every hot day is caused by El Niño. However, the combination of warm Pacific events and steadily rising temperatures, which the World Meteorological Organization has repeatedly warned about, means developers and owners can no longer treat thermal comfort as a secondary detail. A building that is uncomfortable on a summer afternoon can become a business continuity problem when the heat lasts several days in a row.

This is where a certified building makes a difference. Not because certification is an automatic shield, but because it requires data-driven design decisions, verification that those decisions were carried out, and measurement of results during operation.

Why certified buildings handle heat better

A conventional building tends to respond to heat with a single question: how many air conditioning units do we need? A certified building starts with a different one: how do we keep the heat out?

This approach rests on three principles shared by EDGE and LEED:

  1. Reduce heat gain through architecture: external shading, solar control glazing, insulation and reflective roofs.
  2. Handle the remaining thermal load with efficient systems: properly sized equipment, zone-level controls and energy monitoring.
  3. Verify and measure: confirm that what was designed actually works and track results over time.

The result is an asset that uses less energy on a normal day and, during an extreme event, has more margin to maintain comfort without compromising operations.

EDGE: measurable efficiency for projects that need financial clarity

EDGE certification, developed by IFC (a member of the World Bank Group), requires a project to achieve at least 20% savings in energy, water and embodied energy in materials compared with a local baseline building. When it comes to extreme heat, its value lies in letting teams test design measures and see their impact before construction.

Using the EDGE tool, the project team can compare options such as:

  • External shading on critical façades, especially west-facing ones.
  • Glazing with a lower solar heat gain coefficient, which reduces the solar radiation entering the building.
  • Thermal insulation in roofs and walls, essential on top floors and in low-rise buildings.
  • Reflective roofs that absorb less heat.
  • Efficient HVAC and lighting equipment, which uses less energy and generates less internal heat.

For developers of residential, office or retail projects, EDGE turns heat adaptation into a decision backed by clear numbers: which measures improve comfort, how much they save and which ones make financial sense. With the EDGE Advanced and EDGE Zero Carbon levels, projects can go even further in reducing energy use.

LEED: a comprehensive approach to resilience

LEED takes a broader view of building performance. Several of its credits directly address the risks that come with El Niño:

  • Heat island reduction: encourages high-reflectance roofs and paving and shaded areas, reducing heat buildup in the building and its surroundings.
  • Optimize energy performance: requires modeling the building and improving its efficiency against a baseline, which lowers the cooling load.
  • Thermal comfort: calls for systems designed to maintain suitable conditions for occupants and give them control over their environment.
  • Commissioning: verifies that HVAC and control systems perform as designed, one of the areas where conventional buildings lose the most efficiency.
  • Advanced energy metering: makes it possible to detect abnormal consumption and respond quickly during demand peaks.
  • Rainwater management: highly relevant in an El Niño year, when heavy rainfall also puts buildings to the test.

In addition, the latest version, LEED v5, strengthens the focus on climate resilience by asking projects to assess the climate risks they face and plan how to respond to them.

WELL and Fitwel: heat is also a health issue

A building can use little energy and still have overheated zones, glare or poor air quality. WELL and Fitwel certifications put the focus on occupants: thermal comfort affects productivity, satisfaction, absenteeism and the perceived quality of the asset. In a demanding summer, this matters as much as the electricity bill.

Existing buildings can prepare too

Most buildings in Peru have already been built, so adaptation can't rely on new projects alone. Before the hot season, an existing building can:

  • Review HVAC schedules and temperature settings by zone.
  • Carry out preventive maintenance on filters, coils and equipment.
  • Install external shading or solar films on the most exposed façades.
  • Apply reflective coatings to roofs.
  • Seal air leaks around doors, windows and loading docks.
  • Switch to LED lighting with sensors, because every watt of lighting saved means less heat inside the space.
  • Measure temperature, humidity and energy use before and after each intervention.

These actions are also the starting point for certifying buildings in operation, a path increasingly used by owners and funds that want to demonstrate the real performance of their assets.

Lima, Piura, Iquitos and Cusco: each city needs its own strategy

El Niño doesn't affect the whole country in the same way, and certifications make it possible to tailor solutions to the local climate:

  • Northern coast (Piura, Tumbes, Chiclayo): more intense heat and humidity, plus heavy rainfall. Solar control, dehumidification and stormwater drainage should be priorities.
  • Lima: façades exposed to the afternoon sun and high humidity. Zone-adjustable systems work better than rigid solutions.
  • Amazon region (Iquitos, Pucallpa): constant heat and humidity. Deep shading, a well-designed building envelope and humidity control are essential.
  • Andes (Cusco, Arequipa): strong solar radiation during the day and cold nights. Insulation, thermal mass and good orientation are needed to respond to the full daily cycle.

Thermal resilience is now part of real estate value

Investors, tenants and financial institutions are paying closer attention to how an asset manages its energy use, its climate risks and the experience of its occupants. A certified building can prove it with data, while others can only promise it in their marketing materials. In an El Niño year, that difference shows up in operations, in the electricity bill and in the value of the asset.

  • If you're a developer, build certification into the feasibility stage, when adjusting a façade or a roof is still a design decision rather than a costly retrofit.
  • If you own an existing building, start with an assessment of the building envelope, systems and actual energy use.
  • If you're a tenant company, ask about thermal comfort and the building's certification before signing a long-term lease.

El Niño isn't solved by turning down the thermostat. It's addressed with buildings that reduce heat from the design stage, use energy precisely and protect the health of the people inside them.

Is your project ready for next summer? At Leaf, we guide you through EDGE, LEED, WELL and Fitwel certification, from design to operation. Calculate your certification here.